AGA Medical Corporation
ProductsPatients & FamiliesFacility LocatorAbout AGAClinical Trials

International Products

AMPLATZER® VSD Occluders for Ventricular Septal Defect Closure

Availability: International

AMPLATZER® VSD Occluders for complex ventricular septal defect (VSD) repair in patients considered to be high risk for standard transatrial or transarterial surgical repair. Polyester fabric inserts help close the hole and provide a foundation for growth of tissue over the occluder after placement.

Indications, contraindications, warnings, precautions and instructions for use can be found in the Instructions For Use supplied with each device.

AMPLATZER® Membranous VSD Occluder

AMPLATZER® Membranous VSD Occluder

AGA Medical designed the AMPLATZER® Membranous VSD Occluder to allow closure of membranous ventricular defects using a minimally-invasive catheter procedure instead of surgery.

The Membranous VSD Occluder has a special asymmetrical shape to fit the occluder in the upper portion of the ventricles while avoiding contact with the aortic valve in the left ventricle.

The physician deploys the occluder to expand each disc on either side of the defect, closing off the hole.

 

AMPLATZER® Muscular VSD Occluder

AMPLATZER® Muscular VSD Occluder

AGA Medical designed the AMPLATZER® Muscular VSD Occluder to allow closure of muscular ventricular defects using a minimally-invasive catheter procedure instead of surgery.

The Muscular VSD Occluder has two concentric discs and a wide waist to accommodate the thicker portion of the ventricular septum.

The physician deploys the occluder to expand each disc on either side of the defect, closing off the hole.

 

AMPLATZER® P.I. Muscular VSD Occluder

AMPLATZER® Muscular VSD Occluder P.I.

The AMPLATZER® Post Myocardial Infarction (P.I.) Muscular VSD Occluder device is an extension of the AMPLATZER Muscular VSD Occluder family. Patients with acute VSD rupture following myocardial infarction are primarily adults with a “thicker” ventricular septum. The length of the standard AMPLATZER Muscular VSD Occluder is 7 mm long. The length of the waist in the AMPLATZER P.I. Muscular VSD Occluder is 10 mm to allow the device to be used in adult patients post-MI.

Video Demonstrations

THE AMPLATZER Membranous VSD Occluder

Membranous VSD Occluder Placement

THE AMPLATZER Muscular VSD Occluder

Muscular VSD Occluder Placement

Patient Informational Guide on Muscular VSD Closure

Muscular VSD Patient Guide - English and Espanol
The PDF provides a useful informational booklet about Muscular VSD and closure using the AMPLATZER® Muscular VSD Occluder, in English and Spanish. For additional information contact AGA Medical.

 

For Medical Professionls

Guidelines & Downloads

To Find a Physician:

Use our Facility Locator

Contact Us:

United States
AGA Medical Corporation
5050 Nathan Lane North
Plymouth, MN 55442
USA

Toll Free: 1-888-546-4407
Phone: 1-763-513-9227
Fax: 1-763-513-9226

United Kingdom
AGA Medical Ltd
Suite 1
3500 Parkside
Birmingham Business Park
Birmingham
B37 7YG

Phone: 0121-788-4610
Customer Services: 0121-788-4620
Fax: 0121-788-2142

Germany
AGA Medical Deutschland GmbH
Speicherstrasse 57
60327 Frankfurt

Phone: 069-907483-300
Customer Service: 069-907483-325
Fax: 069-24249621

Spain
Amplatzer Medical España S.L.
Parque Empresarial Alvento,
Calle Via de los Poblados 1,
Edificio D, Bajo C
28033 Madrid
Spain

Phone: 0 34-91-3823030
Customer Service: 0 34-91-3823010
Fax: 0 34-91-3818628

France
Amplatzer Medical France SAS
47-53 rue Raspail
92300 Levallois-Perret

Phone: 01-40-87-25-30
Fax: 01-40-87-25-31

Latin America
Avenida Libertador 2442
Olivos, Buenos Aires 1636
Argentina

Phone: 54-11-4711-8278
VoIP Phone: +1-763-531-3009

Asia Pacific
Suite 811, Tsimshatsui Center
East Wing, 66 Mody Road
Tsimshatsui, Kowloon, Hong Kong

Phone: 2268-6566
Fax: 2268-6741